Measurement output: batched measurements from the connector

By default a connector publishes one sample per reading, and the ot-measurement flow in the thin-edge.io mapper turns each sample into a measurement. That works for a few thousand readings per second. Every sample is a message, and every message runs JavaScript in the mapper: about 0.5 ms of mapper CPU per reading with the ot-* flows installed.

With measurement output the connector publishes the thin-edge measurements itself, hundreds of readings per message, and publishes samples only for the points a flow still needs. No JavaScript runs for a measurement, and the mapper only converts it. In the performance harness (doc/performance.md) this took the mapper from about 145 % of a core at 4,000 readings/s to about 10 % at 100,000 readings/s.

The normative rules are in contract §5.5. This guide explains how to use them.

Set output in the [connector] table and leave the flows installed:

[connector]
protocol = "opcua"
output = "measurements"

Both builds support it, for every protocol, and nothing else in the configuration changes. To switch back, remove the key or set output = "samples". The flows still handle samples.

What changes on the broker:

output = "samples" (default)output = "measurements"
Measurements on te/device/<device>///m/<group>One per reading, from ot-measurementBatched, from the connector
Units on te/device/<device>///m/<group>/metaFrom ot-measurementFrom the connector
Samples on te/device/<device>/ot/<protocol>/sample/<point>Every readingOnly for points that flows read, or sample = true
Link status, capability descriptor, commandsUnchangedUnchanged

A reading becomes the series <group>.<series> with the rules the ot-measurement flow uses, so the cloud sees the same names in both modes:

  1. the point’s meta.measurement.group and meta.measurement.series
  2. the [connector] table’s measurement.group and measurement.series
  3. the point id split at measurement.point_separator, when one is set and the id contains it
  4. the protocol id as the group and the point id as the series
[connector]
protocol = "modbus"
output = "measurements"
measurement = { point_separator = "." } # "Environment.Temperature" -> Environment / Temperature
[[device]]
name = "plc1"
protocol_address = { transport = "tcp", host = "10.0.0.5", port = 502, unit_id = 1 }
[[device.point]]
id = "boiler_temp"
datatype = "float32"
unit = "°C"
address = { table = "holding", address = 7, count = 2 }
meta = { measurement = { group = "Boiler", series = "Temperature" } }

Only a good reading of a number or a boolean becomes a series. A boolean is published as 1 or 0 unless measurement.include_boolean = false. Strings, 64-bit integers outside the JavaScript safe range, raw points and points with meta.measurement = false never become series.

The [connector] measurement keys are the ot-measurement flow’s parameters of the same names. The flow’s own params.toml does not apply to a connector in measurement output, so copy any group, series, point_separator or include_boolean you set there into the connector’s configuration.

A thin-edge measurement has one time, so readings share a message only when they share a time. Which time a reading has, and how readings are grouped, is the point’s batch policy. Set it on [connector], a device or a point; it is merged key by key like report.

group_byMessage timeLossUse it for
"time" (default)The reading’s own timeNone, and no time is movedPolled points. A polled pass shares one read time, so it is one message per device and group.
"frame", window = "500ms"Each layer’s first reading’s time in the windowNone. A time moves by less than windowPushed points whose source times differ by a few milliseconds
"sample", every = "1s"The sample timeReadings superseded between two samplesA fixed rate per point, whatever the source sends

Readings with the same timestamp, at millisecond precision, go into one message. A polled read returns all its points with the completion time of the read call, so a pass over a device is one message per group. Pushed values carry the time the source reports (an OPC UA source timestamp), so pushed points batch only as far as their times coincide. No reading is lost and no time is changed.

[[device]]
name = "line1"
batch = { group_by = "frame", window = "500ms" }

Readings that arrive within window share a message stamped with the first reading’s time, and the messages are published when the window ends. A point that changes twice within a window does not end the message: its second value goes into a second message of the same window (a layer), its third into a third, and so on. Every value reaches the cloud, and a window of 1,000 changing points usually needs only a few messages.

The price is the time: a reading can be published with a time up to window earlier than its own, and a repeated point’s earlier value waits for the end of the window. Choose a window shorter than the time resolution you care about. 500 ms suits most pushed telemetry. With a shorter window each device publishes at least one message per window: ten per second at 100 ms against two at 500 ms, whatever the batching. The mapper’s cost is per message.

Each layer is stamped with its first reading’s time. When source times jitter, that time can be earlier than the previous layer’s; the layer is then stamped 1 ms after the previous one, so a point’s values always reach the cloud in the order they were read and the latest value in Cumulocity is the latest reading.

A point with report = { min_interval = ... } of at least the window never changes twice within one window, so its frame is always a single message.

[[device]]
name = "line1"
batch = { group_by = "sample", every = "1s" }

Every every, the connector publishes the latest good value of every point, stamped with the sample time, whether the value changed or not. Readings between two samples are not published. A point is left out while its value cannot be trusted: its device link is not connected, its subscription failed its check, or its last reading was not good. Points that raise an event for every reading (meta.event.every) are still published one by one, with their own times.

Aggregating: the mean, minimum and maximum of each period

Section titled “Aggregating: the mean, minimum and maximum of each period”

Sample-and-hold publishes one reading per period and drops the rest, so a spike between two samples never reaches the cloud. aggregate publishes a value that accounts for every reading of the period instead:

[[device]]
name = "line1"
batch = { aggregate = ["mean", "min", "max"], every = "1s" }

aggregate implies group_by = "sample", so the every is all it needs. Each second the connector then publishes, for every point of line1:

SeriesValue
<series>_meanThe time-weighted mean: each value counts for as long as it held during the second. A value of 10 that changes to 20 at 900 ms gives 11, not 15. For evenly polled points this is the plain average.
<series>_min, <series>_maxThe smallest and largest value the point held during the second, including the one it held when the second started.
<series>_lastThe value held at the sample time, as sample-and-hold publishes it.
  • A single name, such as aggregate = "mean", publishes the mean under the point’s own series name, so dashboards and alarms on that series keep working.
  • A list publishes each aggregate with the suffix _<aggregate>, and the units message gives each of them the point’s unit. A suffixed name that is already another series of the device’s group is refused when the configuration loads.
  • A boolean counts as 1 or 0, so its mean is the fraction of the period it was true: a duty cycle.
  • Time while the point is stale (its device link is down, its subscription failed its check, or its last reading was not good) does not count. The mean of a period with a 10 for half of it and an outage for the rest is 10. A period with no good time leaves the point out.
  • Periods start when the configuration is loaded, not on the wall clock’s whole seconds.

An aggregate uses every reading, so it cannot be combined with report: a point whose policy has both is refused when the configuration loads. To publish less often, use a longer every.

Each aggregate in a list is a series of its own: three aggregates publish three times the series, and so about three times the messages and mapper work of sample-and-hold. A single aggregate costs the same as sample-and-hold.

The reporting policy (report, see reducing data volume) runs first. A reading it withholds never reaches the measurements. Under "sample" the last reported value is sampled again, so report and "sample" together give a fixed rate of values that changed meaningfully. A point with an aggregate cannot have a report policy (see above).

In measurement output a point still publishes samples when a flow reads them:

  • meta.alarm (the ot-alarm flow) or meta.event (ot-event)
  • meta.parameter, or write or read_write access (ot-parameter-state)

Such a sample carries "measured": true when the reading also became a series, and ot-measurement skips it, so the cloud receives each value once.

Another consumer of the samples, such as your own flow or a tool subscribed to the sample topics, sets sample = true on the points it reads. sample = false stops a point’s samples even when a flow would read them.

[[device.point]]
id = "spindle_load"
datatype = "float32"
address = { node_id = "ns=2;s=Spindle.Load" }
sample = true # read by a custom flow

ot-alarm and ot-event used to subscribe to every measurement, for their measurement-series mode: one series watched with a threshold, or an event on every change of one series. With the connector publishing batches, that would run both flows on every batch. That mode is now the separate flows ot-alarm-series and ot-event-series, with the same parameters:

  • The package installs them from /usr/share/tedge-dot/flows/ into the mapper only when an existing ot-alarm or ot-event params.toml sets series, and copies that params file over.
  • To use one on a new installation, copy its directory into /etc/tedge/mappers/c8y/flows/ and write its params.toml from the template.
  • Declaring the alarm on the point (meta.alarm) is the cheaper option: it works in both output modes and needs no flow on the measurements.

The capability descriptor on te/device/main/service/<service>/ot/capabilities lists each device’s output and grouping policy:

"outputs": [
{ "device": "line1", "output": "measurements", "batch": { "group_by": "frame", "window": "500ms" } }
]

To see the measurements and their units:

Terminal window
tedge mqtt sub 'te/device/+///m/#'

A message is split before its Cumulocity size passes about 15,000 bytes, so a device with thousands of points in one group sends several messages per pass, each with the same time. The mapper rejects nothing: its limit is 16,184 bytes.

  • The ot-measurement flow’s deprecated filters (on_change, deadband, min_interval, debounce) and its combine mode do not apply to a connector in measurement output. Use the point’s report table and batch instead.
  • tedge-dot run --output stdout prints samples in both modes.
  • Units are published per measurement topic from the connector’s configuration. Two connectors that publish the same device and group overwrite each other’s units message; give their points different groups.