The OT Connector Contract

FieldValue
StatusNormative draft
Version0.4.0
Date2026-10-29
Schemasschemas/ · asyncapi.yaml

This document defines the OT Connector Contract: the protocol-neutral interface every connector exposes to the rest of thin-edge.io. It is the single source of truth that the SDK, the connector specs, the flows, and the conformance suite all build on.

The keywords MUST, MUST NOT, SHOULD, SHOULD NOT, and MAY are used as in RFC 2119.

This contract is protocol-agnostic. Nothing in it is specific to Modbus, CAN, BACnet, OPC-UA, or any other protocol. Exactly three configuration objects are left opaque for a protocol to define — connection, device.protocol_address, and point.address (§3.2) — and everything else (topics, sample envelope, datatypes, commands, capabilities, status) is identical across protocols. Throughout this document Modbus is used only as a running example to make the abstract structure concrete; wherever you see Modbus terms such as register, coil, or unit id, read them as “this protocol’s equivalent.”


TermMeaning
ConnectorA running instance of tedge-dot using one protocol module.
Protocol moduleThe protocol-specific code (e.g. Modbus) implementing the Connector trait.
DeviceA physical/logical field device the connector talks to (a PLC, a meter, an OPC-UA server). Maps to a thin-edge entity.
PointA single readable/writable datum on a device (a register, a coil, an OPC-UA node, a CAN signal).
SampleThe result of reading a point once, published as a sample envelope.
ModePer-point output selection: raw (bytes) or typed (decoded primitive).
CapabilityA declared feature a connector supports (a point kind, a mode, a command verb).

A connector manages one or more devices; each device has one or more points. The connector reads points (by polling and/or subscription), publishes samples, accepts commands (e.g. writes), and reports status.

All topics live under the thin-edge.io entity tree so the local mapper and flows pick them up naturally. <device> is the thin-edge entity id segment for the device (e.g. plc-1); <protocol> is the protocol module id (e.g. modbus).

PurposeDirectionTopicRetained
Sample (read result)connector → brokerte/device/<device>/ot/<protocol>/sample/<point>no
Connector statusconnector → brokerte/device/main/service/<service>/status/healthyes
Device link statusconnector → brokerte/device/<device>/ot/<protocol>/status/linkyes
Capability descriptorconnector → brokerte/device/main/service/<service>/ot/capabilitiesyes
Command requestrequester → brokerte/device/<device>/ot/<protocol>/cmd/<verb>/<id>yes
Command resultconnector → brokerte/device/<device>/ot/<protocol>/cmd/<verb>/<id>yes
Management command requestrequester → brokerte/device/main/service/<service>/ot/cmd/<verb>/<id>yes
Management command resultconnector → brokerte/device/main/service/<service>/ot/cmd/<verb>/<id>yes

Notes:

  • <service> is the connector service name ([connector] service_name, default tedge-dot-<protocol>). It addresses the connector’s management commands (§6.3), so it must be unique on the broker and cannot be changed by set-config.
  • Samples MUST NOT be retained; they are time series.
  • Status, capability, and command messages MUST be retained so late subscribers and the command state machine observe the latest state.
  • Command request and result share a topic; the payload status field carries the state-machine transitions defined in §6.

Flows are responsible for re-publishing samples into the standard te/device/<device>///m|e|a/... topics. The connector itself MUST NOT publish to the m/, e/, or a/ channels.

Configuration is TOML. The top level is split into a connector section, a connection section (protocol-specific), and a list of devices, each with a list of points. The structure below is protocol-neutral: only the three objects marked protocol-specific (connection, device.protocol_address, point.address) change shape from one protocol to the next (see §3.2). Everything else is identical for Modbus, CAN, BACnet, OPC-UA, and any future protocol.

# /etc/tedge/plugins/ot/<protocol>.toml (protocol-neutral skeleton)
[connector]
protocol = "<protocol>" # protocol module id (MUST match a compiled-in module)
service_name = "tedge-dot-modbus"
poll_interval = "2s" # default poll interval (duration string); per-point override allowed
sampling_interval = "500ms" # optional: default sampling interval of pushed points (§3.1); else poll_interval
log_level = "info"
operation_timeout = "30s" # optional: upper bound on one protocol-module call (§8.1)
stall_timeout = "120s" # optional: restart the connector if its loop stops moving (§8.1)
# optional: where bare point-library names are looked up (§3.4); shown with its default
point_library_path = ["/etc/tedge/plugins/ot/points.d", "/usr/share/tedge-dot/points.d"]
report = { max_interval = "30m" } # optional: default reporting policy for every point (§5.3)
output = "samples" # optional: "samples" (default) or "measurements" (§5.5)
measurement = { point_separator = "." } # optional: measurement naming in measurement output (§5.5)
batch = { group_by = "time" } # optional: default grouping policy in measurement output (§5.5)
max_inflight = 4 # optional: requests in flight to one endpoint (§5.6)
max_inflight_total = 32 # optional: requests in flight across all endpoints (§5.6)
[mqtt]
host = "127.0.0.1"
port = 1883
# Protocol-specific shared connection defaults. Shape defined by each connector spec.
[connection]
# ...
[[device]]
name = "<device-name>" # -> te/device/<device-name>
type = "<device-type>" # optional; what this device IS (§3.1), else from its library
protocol_address = { } # protocol-specific: how to reach this device. Shape per connector spec.
poll_interval = "2s" # optional per-device override
sampling_interval = "500ms" # optional per-device override (pushed points only)
default_mode = "typed" # optional; default output mode for this device's points
points_from = [] # optional; point libraries to inherit points from, in order (§3.4)
enabled = true # optional; false keeps the definition but leaves the device out (§3.3)
report = { on_change = true } # optional: default reporting policy for this device's points (§5.3)
batch = { group_by = "frame", window = "500ms" } # optional: this device's grouping policy (§5.5)
max_inflight = 2 # optional: requests in flight to this device's endpoint (§5.6)
[[device.point]]
id = "<point-id>" # unique within the device; appears in topics
mode = "typed" # "raw" | "typed" (inherits device.default_mode if omitted)
datatype = "float32" # required when mode = "typed"; see §4
endianness = "big" # byte order: "big" | "little" (typed only)
word_order = "big" # multi-word order: "big" | "little" (typed only)
poll_interval = "1s" # optional per-point override
sampling_interval = "200ms" # optional: how often the source samples this point when pushed (§3.1)
address = { } # protocol-specific: how to address this point. Shape per connector spec.
access = "read" # "read" | "write" | "read_write" | "call_method" (default "read")
unit = "raw" # optional free-form hint passed through in the sample
name = "<short label>" # optional human-readable label (§3.1); the id stays an identifier
description = "<what this signal is>" # optional longer explanation (§3.1)
transform = { multiplier = 1, divisor = 1, decimal_shift = 0, offset = 0 } # optional linear scale
# map = { cases = [{ eq = 0, to = "stopped" }, { eq = 1, to = "running" }], default = "unknown" } # optional (§4.3)
report = { deadband = 0.5, min_interval = "10s" } # optional reporting policy (§5.3)
batch = { group_by = "time" } # optional grouping policy in measurement output (§5.5)
sample = true # optional: in measurement output, still publish samples (§5.5)
enabled = true # optional; false keeps the definition but leaves the point out (§3.3)

Example (Modbus). To make the skeleton concrete, here are the same fields populated for a Modbus device. Only the three protocol-specific objects differ from the skeleton; a CAN or OPC-UA example would fill in those same three slots differently while keeping every other field identical.

[connector]
protocol = "modbus"
poll_interval = "2s"
[connection]
serial = { baudrate = 9600, parity = "N", stopbits = 2, databits = 8 } # RTU defaults
[[device]]
name = "plc-1"
protocol_address = { transport = "tcp", host = "192.168.0.10", port = 502, unit_id = 1 }
default_mode = "typed"
[[device.point]]
id = "boiler_temp"
mode = "typed"
datatype = "float32"
address = { table = "holding", address = 7, count = 2 }
[[device.point]]
id = "run_command"
mode = "raw"
access = "read_write"
address = { table = "coil", address = 0, count = 1 }

Reloading. The long-running service applies changed configuration without a restart: on SIGHUP, and on its own when a config file or a point library it references changes. Changes are polled every TEDGE_DOT_CONFIG_WATCH_INTERVAL (default 2s) and applied once they have settled; run --no-watch (or the variable set to 0) leaves SIGHUP as the only trigger. Both triggers run the same reload. A new file starts a connector and a removed one stops it. Every other connector re-reads its file and applies what changed, keeping the configuration it has when the file cannot be used.

3.1 Common (protocol-neutral) point fields

Section titled “3.1 Common (protocol-neutral) point fields”
FieldTypeRequiredNotes
idstringyesUnique within the device; used in sample/<point> and cmd topics.
mode"raw" | "typed"noInherits device.default_mode, else "typed".
datatypestringwhen typedOne of §4’s primitive types.
endianness"big" | "little"noByte order for typed; default "big".
word_order"big" | "little"noWord order for multi-word typed; default "big".
poll_intervalduration stringnoOverrides device/connector default.
sampling_intervalduration stringnoHow often the source samples the point when it is delivered by push, e.g. an OPC UA monitored item’s sampling interval. Overrides the device/connector sampling_interval; with none set, the effective poll_interval is used. Ignored for a polled point. See Sampling interval below.
access"read" | "write" | "read_write" | "call_method"noDefault "read". See Access below.
unitstringnoOpaque hint echoed into the sample for flows.
namestringnoShort human-readable label, for wherever a name is displayed instead of the id — which is a topic segment and a parameter-set key, so it stays a plain identifier. Feeds a parameter’s DTM title (§5.2) and the capability descriptor’s point_labels (§7).
descriptionstringnoLonger human-readable explanation of the signal. Feeds a parameter’s DTM description and point_labels (§7).
transformobjectnoPer-point linear scale (value*multiplier*10^decimal_shift/divisor)+offset; see §4.2.
mapobjectnoThe point’s value map: state codes to labels, numeric ranges to bands with a catch-all, numeric text to numbers. Applied by the SDK runtime after transform on reads and reversed on writes; a later definition replaces it whole. See §4.3.
reportobjectnoThe point’s reporting policy (report by exception): publish only on change or beyond a deadband, rate-limit, debounce, and a heartbeat. Applied by the SDK runtime, not the module; merged key by key over the device’s and [connector]’s report. See §5.3.
metaobjectnoFree-form signal metadata echoed verbatim as meta in every sample envelope. Never interpreted by the connector; flows and tooling read it for per-signal behaviour, for naming the point’s measurement or, with meta.measurement = false, keeping it out of the measurements, for declaring the signal’s alarms and events (meta.alarm, meta.event, read by the ot-alarm / ot-event flows), and for exposing the point as an operator-editable parameter (meta.parameter, see §5.2).
subscribebooleannoDefault true. false keeps the point on the polling schedule even when the connector supports push delivery.
batchobjectnoThe point’s grouping policy in measurement output: group_by ("time", "frame" with a window, or "sample" with an every and an optional aggregate). Merged key by key over the device’s and [connector]’s batch. See §5.5.
samplebooleannoIn measurement output, true keeps publishing the point’s samples for a consumer other than the flows, and false publishes none even when a flow would read them. Unset, the runtime decides. See §5.5.
enabledbooleannoDefault true. false keeps the definition but leaves the point out of the device (§3.3) — how a site switches off one point of a library it does not own (§3.4).

Access. access states what the connector may do with the point:

accessRead (poll, subscribe, heartbeat)write, write-batchcall-method
"read" (default)yesnono
"write"noyesno
"read_write"yesyesno
"call_method"nonoyes

A point that cannot be read is never polled, subscribed or read for a heartbeat, so it never publishes a sample; a write-only point is still written. A "call_method" point is a protocol operation rather than a value — an OPC UA method, for instance — and is called with the call-method verb (§6.6). It is not a value, so it is never a parameter (§5.2) and declares none of the value fields (§3.3). Only a connector listing call-method in its capability descriptor (§7) accepts such points. | address | object | yes | Protocol-specific; shape defined by the connector spec. |

name and description are not echoed in the sample envelope: they are static per point, so the connector publishes them once in its retained capability descriptor (§7) instead of on every read. meta.parameter.title / meta.parameter.description override them for a parameter’s cloud-facing labels, so a point can carry a general-purpose label and still say something different in the parameter UI.

Sampling interval. A point delivered by push (see subscribe above, and the SDK on subscribe) is not polled, but its source may still sample it on a timer and only send changes; an OPC UA server samples each monitored item, for example. sampling_interval sets that timer. The runtime resolves a pushed point’s effective sampling interval as the first one set among the point’s, its device’s and [connector]’s sampling_interval, and otherwise uses the point’s effective poll_interval (so a configuration without the key behaves as before it existed). A sampling_interval at any level wins over every poll_interval. "0" asks the source for its fastest rate; it is never a default. The value reaches the module as the point’s sampling hint (PointRef::interval); a source without a sampling timer (an SNMP trap, a CAN frame) ignores it, and it never changes the polling schedule. To limit how often a point is published, use report.min_interval (§5.3).

A device MAY inherit these same point fields from a point library instead of declaring them inline; see §3.4.

[[device]] type names the device type the instance is one of: what its point list describes, as opposed to protocol_address, which says where to reach it. It is optional, and a device that does not declare one inherits the type of the first point library it references (§3.4) — a library is the point list of one device type, so that is where it is usually declared, once, for every instance.

It matters because it names things that outlive the device: the device’s parameter sets (§5.2), whose names are tenant-wide identifiers in the cloud, and the thin-edge entity type a registration flow assigns. A connector MUST therefore echo it where a consumer needs it without the configuration file: in every sample (§5) and on the link status (§8). Nothing else in the runtime interprets it.

device.protocol_address, connection, and point.address are opaque to the contract: their shape is defined by each connector spec. The contract only requires that they are objects and that each connector documents and schema-validates them.

  • A point with mode = "typed" MUST declare a datatype.
  • A point with mode = "raw" MUST NOT be rejected for missing datatype; decoding fields are ignored.
  • id MUST be unique within a device; name MUST be unique within a connector, and a connector MUST reject a repeated device name rather than let two definitions publish over each other on one entity’s topics. Across the sources a device collects its points from (§3.4) a repeated id is an override, not a duplicate; within one of those sources it is an error.
  • The rules above apply to the resolved point, after every points_from reference has been merged (§3.4).
  • A device type, where present, MUST be a non-empty string; a connector MUST reject a blank one rather than treat it as absent, so the same configuration is accepted by every implementation.
  • A device with enabled = false is not loaded: the connector MUST NOT connect to, poll, describe or answer commands for it, and MUST NOT read anything else about it — its type, its address or its point libraries; only the names of its keys are checked, as for every device (below) — so a configuration can carry a ready-made device switched off, even one whose library is not installed. enabled MUST be a boolean when present (default true), and a disabled device’s name still counts towards uniqueness. The definition stays in the file, so set-config (§6.3, target device:<name>) can switch it on again. A device switched off while the connector runs — by a reload or a restart — is left like a removed one (remove-device): it is no longer polled or answered for, but its retained link status (§8) is not cleared.
  • A point with enabled = false is left out of its device, exactly as if it were not configured: the connector MUST NOT read, subscribe to, write or describe it, and it appears in nothing the connector publishes — samples, the capability descriptor (§7), the link status (§8). The rule applies to the resolved point (§3.4): enabled is replaced like any other field, so a later definition can switch a point back on, and a bare { id = "<point-id>", enabled = false } switches off a point a library supplies. A disabled point is exempt from the completeness rules (an address, a datatype when typed), but what it does declare MUST still be valid, and enabled MUST be a boolean in every definition that carries it (default true).
  • Duration strings follow the thin-edge convention ("500ms", "2s", "5m"): a decimal number and an optional unit — ms (whole milliseconds), s, m or h; no unit means seconds — optionally surrounded by whitespace. Signs, exponents and inf/nan are not durations.
  • A field’s value MUST be valid wherever the definition is written — inline, as a patch of a library point, in a point library, on a disabled point — and an invalid one MUST be rejected at load, naming the point (or device, or [connector]) and the field: an enumerated field (mode, datatype, endianness, word_order, access, default_mode) spelt exactly as listed, a poll_interval that is a duration, unit/name/description strings, address, transform and meta tables, transform numbers (decimal_shift a 32-bit integer), subscribe/enabled booleans, and a map table whose shape and output types are valid (§4.3). The checks of a map against the point’s mode and datatype apply to the resolved point, since a library may declare the map and the site the datatype. A value read leniently instead — an unknown access as "read", an unparseable poll_interval as the device’s — would load and quietly do the wrong thing.
  • A "call_method" point (§3.1) MUST NOT declare mode, datatype, endianness, word_order, transform, map, poll_interval, sampling_interval, subscribe, report or meta.parameter, checked on the resolved point, so a library’s method point patched by the site is checked too. Settings it only inherits from its device or [connector] are not its own and are allowed. A configuration with a "call_method" point MUST be rejected when the connector does not list call-method in its command_verbs (§7).
  • A key the contract does not define MUST be rejected — at the top level, in [connector] and [mqtt], in a [[device]] (a disabled one included), in a point, inline or in a point library (§3.4), in its transform, its map and each of the map’s cases, and in a library’s [library] — naming the key and the table it is in, and the known key it most resembles when one is close. A misspelt setting (polling_interval for poll_interval) would otherwise be accepted and do nothing. The protocol-specific objects (connection, protocol_address, address) are delegated to the connector’s own schema, and meta is free-form.

A device type has the same data points on every instance; what differs from one instance to the next is the connection information. A point library is that point list in its own file, carrying no connection information at all:

/usr/share/tedge-dot/points.d/modbus/acme-meter-v2.toml
[library]
protocol = "modbus" # MUST match the referencing connector's protocol
type = "acme-meter-v2" # optional; the device type these points describe (§3.1)
description = "ACME meter, firmware 2.x" # optional, informational
version = "2.1" # optional, informational
# namespaces = [...] # optional, protocol-specific: see "Library address settings"
[[point]] # exactly the point fields of §3.1/§3.2
id = "boiler_temp"
datatype = "float32"
address = { table = "holding", address = 7, count = 2 }

A device references one or more, in order, and declares only what is per-instance:

[[device]]
name = "plc-1"
protocol_address = { transport = "tcp", host = "192.168.0.10", port = 502, unit_id = 1 }
points_from = ["acme-meter-v2", "site-extras"]

A library holds only [library] and [[point]]. A file that also carries connector, mqtt, connection or device is a connector configuration and MUST be rejected as such.

A points_from entry is either a name or a path; an entry containing /, or ending in .toml, is a path, and a relative path resolves against the referencing configuration file’s own directory. A name is resolved as <dir>/<protocol>/<name>.toml in each directory of the library search path, first match winning:

PrecedenceDirectoryFor
1/etc/tedge/plugins/ot/points.da site’s own libraries; shadow packaged ones of the same name
2/usr/share/tedge-dot/points.dlibraries shipped by a package (a connector’s, or a vendor’s device pack)

[connector] point_library_path (an array of directories, relative ones resolved against the configuration file’s directory) replaces that default path, and MUST therefore name at least one directory — an empty or unusable list is a configuration error, not a way to say “no libraries”, and MUST NOT be read as if the key were absent. Where the key is absent, the TEDGE_DOT_POINT_LIBRARY_PATH environment variable (colon-separated) replaces the default path instead, which is how a source checkout points at its own libraries. Names are protocol-scoped because a point’s address is protocol-specific (§3.2): the same device type can have a library per protocol, and only the connector’s own is ever loaded.

Points are collected in order — each library in the order listed, then the device’s own inline [[device.point]] entries — and a definition whose id already exists patches the one collected so far rather than adding a second point:

  • meta and transform are merged key by key (recursively for meta), so one field can be adjusted without restating the rest;
  • map (§4.3) is replaced whole: its cases are an ordered list, so merging two would mean nothing. map = {} removes an inherited map;
  • every other field, address included, is replaced when the overriding definition declares it (a partly-inherited protocol address is not a meaningful thing). name and description (§3.1) are ordinary scalars under this rule, which is what lets a site relabel an inherited point — one label at a time — without restating its address. enabled is one too, so { id = "<point-id>", enabled = false } switches off an inherited point (§3.3);
  • a field the override does not mention keeps its inherited value.

Inline points are applied last, so a device always wins over the libraries it references. That ordering is what lets a site extend or adjust a packaged list — add a few points, retitle a parameter, slow one point’s poll_interval — without editing the file the package owns and an upgrade replaces.

The validation rules of §3.3 apply to the resolved point: a definition that only ever appears as a patch, with no library supplying the rest, is rejected for the fields it is missing. Within a single library a repeated id is an error, not an override: there is no order in which to apply it.

[library] type names the device type the points describe (§3.1). A device that does not declare its own type inherits it from the first library in points_from that declares one; later references extend that type rather than redefine it (["acme-meter-v2", "site-extras"]), and a type on the device itself wins over every library.

A library that declares no type leaves the device without one: the file name is deliberately not used instead, because the type ends up as a tenant-wide identifier in the cloud (§5.2) and is worth declaring on purpose.

Some protocols need to know what a library’s addresses were written against. [library] namespaces is the one such key today: OPC UA’s namespace table (OPC UA connector spec §3.9). The loader does not interpret it. Instead, every resolved point remembers the [library] table of the library its address came from, and a connector reads its protocol’s settings from there. A definition that replaces the address, inline or from a later library, also replaces that origin, so an inline address always counts as the device’s own. The origin is never written back to a persisted configuration and never appears in a sample.

Resolution happens when the configuration is loaded, so a protocol module, a flow, the capability descriptor and the sample envelopes see no difference between a point that was inherited and one that was written inline. What is not expanded is the configuration document the runtime keeps for the management verbs (§6.3): it retains the points_from reference, so persisting a patched configuration never bakes a library’s points into the operator’s file, and define-device MAY define a device from connection information plus a reference alone. That is the hook for discovery: a mechanism that finds instances on the network (mDNS, a scan, an asset inventory) publishes one small define-device per instance naming a device type it already knows.

A connector MUST report an unresolvable reference as a configuration error naming what it looked for; it MUST NOT silently resolve a device to zero points. A library that declares an empty point list is therefore rejected exactly like one that declares none at all: left to resolve, the device would come up healthy and publish nothing, which is also what a generated library that found nothing would produce.

A reference introduced by a management command (§6.3) MUST be a name, never a path, and MUST be refused before the path is opened. A configuration file is written by whoever administers the device, but a command is a different trust boundary: a reference taken from the broker could otherwise name an arbitrary path and have the connector report what it found there — whether the file exists, and, through a parse error, part of its contents — in the retained command result. Names are all a discovery mechanism needs.

Only what the command changes is judged: the path references a device already had remain valid, so a configuration that legitimately uses the path form still accepts every management verb. A connector MUST therefore compare the patched document against the one it held, not scan the result as a whole.

The same boundary applies to local-only settings: protocol settings that name files on the gateway (a password file, a PKI directory, a client certificate) or relax security (accepting any server certificate, allowing plaintext passwords). A module declares them by key; a management command that adds or changes one, anywhere in [connection] or in a device’s protocol_address, MUST be refused before anything is written, with a reason naming the key but not its value. As above, values the configuration already has stay valid. Removing one is a change too (a device-level false may be what overrides a [connection] opt-in); removing a whole device is not. The OPC UA and SNMP connectors declare theirs in their specifications.

In typed mode the driver applies only primitive decoding. The contract defines this closed set of primitive datatypes:

datatypeMeaningJSON value type
boolsingle boolean (e.g. a Modbus coil/discrete input, a digital signal)boolean
int8 / uint88-bit integernumber
int16 / uint1616-bit integernumber
int32 / uint3232-bit integernumber
int64 / uint6464-bit integernumber (see §4.1)
float32IEEE-754 singlenumber
float64IEEE-754 doublenumber
stringfixed-length text (encoding declared per connector)string
bytesopaque byte run (always emitted as hex)string (hex)

Decoding semantics:

  • Endianness (endianness) selects byte order within the smallest addressable unit.
  • Word order (word_order) selects the order of multi-word reads when a value spans more than one of the protocol’s native words (for example, two Modbus 16-bit registers forming a 32-bit value). Protocols whose values are not word-addressed simply ignore this field.
  • The driver MUST NOT apply renaming, unit conversion, thresholding, or thin-edge JSON shaping. Those are flow responsibilities. (The declared reporting policy, §5.3, is not driver thresholding: like transform, it is a contract-level point field the SDK runtime applies to every connector alike. A module MUST NOT filter samples itself.) The one numeric transform the driver MAY apply is the declared per-point linear transform (point.transform, §4.2): because scaling is an intrinsic property of a signal rather than flow logic, it is a contract-level point field whose math is owned by the SDK. The driver only invokes the SDK helper; it MUST NOT invent any other scaling, offset, or rounding. The declared value map (point.map, §4.3) is the non-linear counterpart; the SDK runtime applies it, never the driver.
  • Bit-field extraction (start bit / bit count within a word) MAY be supported by a connector as a typed refinement and, if so, MUST be declared in that connector’s spec. Doing it in JS is error-prone.
  • Selecting one primitive out of a structured value MAY likewise be supported, and MUST then be declared in the connector’s spec: a field of a structure, or one element of an array, addressed by the point (for OPC UA, address.field and address.index). The selected primitive is decoded and published like any other typed value, so value stays a number, boolean or string and the point carries one value per sample. A structured value is never published whole in typed mode. Bit-field extraction and this selection are the only decoding refinements allowed beyond whole-primitive decode.

int64/uint64 values that exceed JavaScript’s safe integer range (2^53 - 1) MUST be emitted as a JSON string in value, and the connector MUST set value_repr: "string" in the sample (see §5). Flows can then parse with BigInt. Values within the safe range MAY be emitted as numbers with value_repr: "number".

A point MAY declare a transform object. The SDK applies it to the decoded numeric value immediately after primitive decode (and after bit-field extraction):

out = (value * multiplier * 10^decimal_shift / divisor) + offset
FieldDefaultNotes
multiplier1
divisor1A 0 divisor is treated as 1.
decimal_shift0Power-of-ten shift (e.g. -3 divides by 1000); mirrors the legacy decimalshiftright.
offset0Added last.

Rules:

  • The transform applies only to number values. bool, string, and bytes values pass through unchanged, and it is a no-op in raw mode.
  • The scaled value is what the sample’s value/value_repr carry; raw always remains the unmodified wire bytes.
  • The math is owned by the SDK so every connector scales identically. Connectors invoke the SDK helper rather than re-implementing it.

Writes run the transform in reverse. A write request carries the value in the same engineering units as the sample’s value (§6.2), so before the connector encodes it the SDK maps it back to the raw value:

raw = (value - offset) * divisor / (multiplier * 10^decimal_shift)
  • The same 0 divisor rule applies. Only number values of typed points are inverted; bool and string values, and raw writes, are passed to the connector unchanged.
  • For an integer datatype (int8 … uint64, including bit-field points) the result is rounded to the nearest integer, ties away from zero, so 21.5 with multiplier = 0.1 writes 215 rather than a truncated 214. Float datatypes keep the unrounded value, so a writable point with a transform whose device value is an integer must declare that integer datatype (the raw type), not a float — e.g. an SNMP integer/timeticks object scaled by divisor = 100 is datatype = "int32"/"uint32", otherwise 2.3 inverts to 229.99999999999997 and the connector rejects the fractional value.
  • The raw value must fit the datatype: one outside its range (e.g. -45 with offset = -40 on a uint16, which inverts to -5) fails the write rather than wrapping.
  • A transform whose scale multiplier * 10^decimal_shift is 0 has no inverse, and a value whose raw result is not finite cannot be written: the write is failed with a reason and nothing is sent to the device.
  • The SDK applies the inverse once, on every write path (write, each entry of write-batch, and the CLI write); connectors never apply the transform on write. A point with a value map (§4.3) has the written value mapped back to the device value first.

A point MAY declare a map that converts its value between the device’s representation and the one its samples carry: an operating state code to a label, ranges of codes to a band with a catch-all, a number stored as text to a number (so it can become a measurement). It is the non-linear, type-changing counterpart of transform and, like it, a contract-level point field whose rules the SDK owns: the SDK runtime applies it to every connector alike, and a connector never sees it.

[[device.point]]
id = "op_state"
datatype = "uint16"
access = "read_write"
map.cases = [
{ eq = 0, to = "stopped" },
{ eq = [1, 5], to = "running" }, # several codes, one label
{ min = 10, max = 19, to = "warning" }, # inclusive range: read-only
{ min = 20, to = "fault", write = 20 }, # open range with a write value
]
map.default = "unknown" # catch-all
[[device.point]]
id = "level_text"
datatype = "string"
map = { as = "number" } # "21.5" <-> 21.5
KeyTypeMeaning
casesarray of tablesEvaluated in order; the first matching case gives the output.
cases[].eqnumber, string, bool, or a non-empty list of themMatch a value equal to this one (or to any entry of the list).
cases[].min / cases[].maxnumberA numeric range, both bounds inclusive, either one omitted for an open range. A case has eq or a range, not both.
cases[].tonumber, string or boolThe output.
cases[].writenumberRange cases only: the device value a write of to sends. It MUST lie within the range.
defaultnumber, string or boolThe output for a value no case matches.
as"number", "string" or "bool"Convert a value no case matches to this type. Cannot be combined with default.

Reads. The map applies after primitive decode and transform, so range bounds are in the point’s engineering units, and before the reporting policy (§5.3), which therefore compares the mapped value. Matching:

  • Numbers compare numerically; a 64-bit integer carried as a string (§4.1) compares as that integer, exactly. Strings compare exactly and case-sensitively; a bool matches only a bool. There is no coercion: a numeric eq never matches the text "1" (use as). NaN matches no case.
  • A value no case matches takes default, else the as conversion, else the sample is published quality = "bad" with no value and error = "point <id>: no mapping for value <v>". That is a mapping failure, not a failed read: it does not affect the link status (§8), reconnects or liveness.
  • as conversions: number — a string is parsed as a decimal ([+-]?(digits[.digits?] | .digits)([eE][+-]?digits)?, surrounding whitespace ignored, finite; no hexadecimal, inf or nan), a bool is 1/0; string — a number becomes the shortest decimal digits that read back as the same number, in positional notation (0.1, 12, 1000000000000000000000, never an exponent; -0 is 0), a bool "true"/"false"; bool — a number is true unless it is 0, a string is true for true/1/on/yes and false for false/0/off/no (any case, whitespace trimmed). A value already of the type is unchanged; one that cannot be converted makes the sample bad, as above.
  • A mapped sample carries source_value (and source_value_repr): the value before the map, after transform — the code behind the label (§5). bad samples of failed reads carry no value and are untouched.

Writes. A write carries the mapped value (§6.2), so the SDK maps it back to the device value before the inverse transform (§4.2) and the encoding: it takes the first case whose to equals the written value (compared as above) and writes that case’s eq (the first entry of a list) or its range’s write. A range without write is read-only, so a later case with the same to may still supply the write. With no such case and an as, it writes the reverse conversion into the point’s own type (21.5 → "21.5" for a string point). The write is failed, and nothing is sent to the device, when the written value’s type is not the map’s output type, when it matches only default (never writable) or nothing, or when the reverse conversion fails; the reason lists the accepted values. A raw write (§6.2) bypasses the map.

Validation (at load and on reload, naming the device, the point and the key or case): default and as together; outputs (to, default, the as type) of more than one type — every map publishes one value_repr; a case without to, with both eq and a range, with neither, with an empty eq list or with min > max; write outside its range or on an eq case; a range on a string or bool point; an eq of a type the point’s value can never be; a map on a raw-mode or bytes point. A map with none of cases, default and as is refused, except the empty table, which means no map.

Test vectors both SDKs run are in test-vectors/map/.

Every successful or failed read produces exactly one sample message on te/device/<device>/ot/<protocol>/sample/<point>. JSON Schema: schemas/sample.schema.json.

The envelope is protocol-neutral; only the addr object is protocol-specific (it echoes the native address so flows can route or debug). The example below uses Modbus to make it concrete:

{
"ts": "2026-05-30T10:00:00.000Z",
"ts_ms": 1780221600000.0,
"device": "plc-1",
"type": "acme-meter-v2",
"protocol": "modbus",
"point": "boiler_temp",
"mode": "typed",
"datatype": "float32",
"value": 42.5,
"value_repr": "number",
"raw": "422a 0000",
"quality": "good",
"unit": "raw",
"addr": { "table": "holding", "address": 7, "unit_id": 1 },
"seq": 12407
}
FieldTypeRequiredNotes
tsstring (RFC 3339, ms, UTC Z)yesThe reading’s time: the source time when the protocol gives one (an OPC UA source timestamp), else the completion time of the read call, shared by every sample of the call (§5.4).
ts_msnumbernoThe same instant as Unix epoch milliseconds (float); the numeric companion to ts for consumers doing time arithmetic.
devicestringyesthin-edge device entity id segment.
typestringnoEcho of the device’s declared type (§3.1), when it has one. Lets consumers name the point’s parameter set (§5.2) without the configuration file.
protocolstringyesProtocol module id.
pointstringyesPoint id.
mode"raw" | "typed"yesEchoes the point mode.
datatypestringwhen typedThe primitive type decoded.
valuenumber | boolean | stringwhen quality = goodDecoded value (typed) — absent for raw.
value_repr"number" | "boolean" | "string"when value presentTells flows how to interpret value. For a mapped point (§4.3) it is the map’s output type, while datatype still names the device primitive.
rawstring (hex, space-grouped per word)yesThe bytes read; always present in both modes. For a structured value read in raw mode it is the encoded body, and the connector’s spec says how addr identifies its type.
quality"good" | "bad" | "stale"yesSee §5.1.
unitstringnoEcho of the point’s unit hint.
access"read" | "write" | "read_write"noEcho of the point’s declared access (SDK runtimes always set it). Lets consumers tell writable points apart without the configuration file (§5.2).
addrobjectyesProtocol-specific address echo (for flow routing/debug).
seqintegernoMonotonic per-point counter of published samples; helps detect drops. Readings withheld by the reporting policy (§5.3) do not consume a number, so a gap always means a published sample was lost.
errorstringwhen quality = badHuman-readable failure reason.
source_valuenumber | boolean | stringnoMapped points only (§4.3): the value before the point’s map, after transform — the code behind a label. Present whenever the read produced a value, including when the map has no output for it.
source_value_repr"number" | "boolean" | "string"with source_valueTells flows how to interpret source_value.
metaobjectnoThe point’s meta table echoed verbatim by the runtime (§3.1); carries per-signal hints for flows.
measuredbooleannotrue when the connector, in measurement output (§5.5), also published this reading as a series. A flow converting samples into measurements MUST skip it. Absent otherwise.
qualityMeaningvalue present?
goodRead succeeded; value is current.yes (typed) / raw only (raw mode)
badRead failed (timeout, exception, CRC). error set.no
staleLast good value re-emitted because a refresh failed but cached data exists.yes
  • In raw mode there is no value; the payload is the raw hex. quality still applies (a failed raw read is bad with no raw, or raw omitted).
  • A connector MUST publish bad samples for failed reads rather than silently dropping them, so flows and operators can react. A connector MAY rate-limit repeated bad samples.

5.2 Parameters (writable points as device state)

Section titled “5.2 Parameters (writable points as device state)”

A point whose access permits writes is, to an operator, a parameter: a setting with a current value and a control to change it. The contract deliberately adds no mechanism for this beyond echoing access, meta and the device type in samples: a flow (ot-parameter-state) derives one retained twin fragment per parameter set from the samples and acknowledged writes, and cloud-specific tooling (tedge-dot describe) renders the same sets as cloud-side definitions. A read-only point can opt in with meta.parameter = true, a writable point can opt out with meta.parameter = false. A parameter’s key inside its fragment is its point id, or meta.parameter.key when the point names one — so a point can keep an id that is unique on the device (firmwareVersion) and still be version in its firmware set with meta.parameter = { key = "firmware.version" }: a key <set>.<key> names its set too (absolutely, so it cannot be combined with set or group), while a key without a dot stays in the point’s usual set (and cannot be combined with set). Keys SHOULD be plain identifiers ([A-Za-z0-9_]) and unique per set on a device. The capability descriptor lists every point that names a key (parameter_keys, §7), so consumers know the keys before any sample: after a restart, since samples are not retained, and for a write-only point, which never samples.

Literal parameters. A point that needs no set names a fragment with meta.parameter = { fragment = "<name>" } and is published as that fragment: its value IS the fragment ("pump_speed": 42), not a key in an object. The name is used verbatim, like set, and SHOULD be a plain identifier. A literal is in no set, so fragment cannot be combined with set, group or key. One name is either a literal fragment or a set, never both, on any device of the tenant. The presentation options (title, description, min, max, enum, default) keep their meaning. The capability descriptor lists every literal in parameter_keys (§7) with its fragment, for the same reason it lists keys.

Naming a set. A set name is a tenant-wide identifier in the cloud, so it is qualified by the device type (§3.1) — what decides which points exist — and never by the protocol alone, which says nothing about them:

<device type, else the protocol>_<group, default "control">_parameters

Every run of characters outside [A-Za-z0-9] folds to a single _, so acme-meter-v2 with the default group gives acme_meter_v2_control_parameters. Two knobs refine it, both under meta.parameter:

KeyMeaning
groupA second set of the same device type (commissioning → acme_meter_v2_commissioning_parameters).
setAn absolute name, used verbatim — the escape hatch for an identifier that predates this rule, or for a set deliberately shared by several device types. A bare string (meta.parameter = "pump") is this form.

Either key MAY be a list, and the point then belongs to every set it names — operators group signals by what they are for, and one setpoint can belong on the commissioning screen and the daily-operation one:

meta.parameter = { group = ["control", "commissioning"] }

Such a point is a property of each of those definitions, and its value is published to each of their fragments, so the groups never disagree about it. Empty lists and non-string entries are ignored (a list that names nothing usable behaves like no list at all), names that fold to the same set are not repeated, and an absolute set still wins over group.

A device with no declared type falls back to <protocol>_control_parameters, which every other device type on that protocol also falls back to: fine for a fleet of one type, a collision for a fleet of several, and the reason tedge-dot describe warns about it. Consumers derive the same name from the device type echoed in samples and on the link status, so the connector, the flows and the cloud-side definitions agree without sharing a configuration file.

Keeping a set current. A fragment must hold exactly the parameters the device has now: Cumulocity sends the whole fragment back with an operator’s edit, so a key for a point that is gone fails every update of that set. The flow therefore drops a point from every set when the link status (§8) no longer lists it, and from a set its latest sample no longer names (its group, its type or its access changed); a set left with no points is cleared with an empty retained message rather than published as {}. A fragment the flow no longer holds in memory — published before the mapper restarted, for a set with no configured point left — is the one case it cannot see, and is cleared by hand (see RFC 0005).

A mapped point (§4.3) is a parameter like any other: its fragment holds the mapped value (the label), an operator’s edit is written as that label and the SDK maps it back, and tedge-dot describe renders the property with the map’s output type and, when its writable values form a closed set (no as), lists them as the property’s enum, so the cloud offers a choice. The datatype’s range does not apply to a mapped property; meta.parameter.enum, min and max still win.

See RFC 0003 and RFC 0005.

5.3 Reporting policy (report by exception)

Section titled “5.3 Reporting policy (report by exception)”

By default every reading is published. A point MAY declare a reporting policy that publishes it only when it matters — on a change, on a change beyond a deadband, at most so often, once a new value has settled — and a heartbeat that still publishes it now and then when nothing changes. The policy is applied by the SDK runtime in front of the sample topic, so every consumer (flows, alarms, the parameter twin, third-party tools) and the broker itself see the reduced stream, and every connector behaves identically. It is configured, not coded:

[connector]
report = { max_interval = "30m" } # heartbeat for every point
[[device]]
name = "plc-1"
report = { on_change = true } # this device's points: only on change
[[device.point]]
id = "boiler_temp"
report = { deadband = 0.5, min_interval = "10s" } # ...and this one beyond 0.5, at most every 10 s
KeyTypeMeaning
on_changebooleanPublish only when the value differs from the last published one.
deadbandnumber, or string "<p>%"Publish only when the value moved at least this much from the last published one: an absolute amount in the point’s (transformed) units, or p percent of the last published value’s magnitude. Implies on_change. Numeric values only.
min_intervaldurationPublish at most once per interval. A change arriving sooner is held and published when the interval ends (with its own ts), never dropped.
max_intervaldurationHeartbeat: publish the point’s next fresh reading once this long has passed since its last publish, even if unchanged.
debouncedurationPublish a changed value only once it has stayed the same (within the deadband, if one is set) for this long. Implies on_change.

A duration of "0", on_change = false and deadband = 0 switch a setting off, which is how a more specific level turns off one it inherits.

Inheritance. The effective policy of a point merges, key by key and each winning over the ones before it: [connector] report, the device’s report, the point’s report in a point library (§3.4), and the point’s report in the configuration. A single report table that sets max_interval not greater than min_interval is refused; when that only arises through inheritance, the effective heartbeat is raised to twice min_interval and a warning names the point.

Rules (per device and point):

  1. Always published, whatever the policy: the first reading after the connector starts, after an applied reload or management command (§6.3), after the device reconnects, after a write, write-batch (or other write) command to the device (a rejected or clamped write reads back unchanged, while the parameter twin already shows the written value), and after the connection to the broker is restored; and any reading whose quality differs from the last published one. Publishing a quality change discards a held reading, so an older good value never follows a newer bad one.
  2. Change. Numbers (value_repr = "number") compare numerically after transform: any difference above 1e-9 with on_change alone, at least the deadband when one is set (with a percent deadband and a last value of 0, any change). NaN equals only NaN. Everything else — booleans, strings, 64-bit integers carried as strings (§4.1), raw points — compares by exact equality of value_repr and value (or raw when there is no value); the deadband does not apply to them. A mapped point (§4.3) is compared by its mapped value, so two codes with one label are no change, and a deadband applies only when the map’s output is a number.
  3. Deadband drift. Differences are measured from the last published value, so a slow drift is reported once it adds up to the deadband.
  4. Heartbeat. A heartbeat never re-publishes an old reading. A polled point’s next poll is published; a pushed (subscribed) point is read on demand, at most once per max_interval. A failed or timed-out read publishes a bad sample (and affects the link status like a failed poll), so a dead source is reported rather than hidden. A point the module cannot read on demand — an SNMP trap, a CAN frame — gets no heartbeat.
  5. Timing. Held and debounced readings are published on the first pass of the runtime’s loop after their interval ends, keeping the ts of the reading.
  6. seq counts published samples only (§5).
  7. Replayed readings. A module that delivers history after the fact (an archive read after an outage) marks those pushed samples as replayed (replayed in both SDKs) and gives each its source time. For a replayed reading, min_interval, debounce and max_interval are measured on source time, so a burst of history is reduced exactly as the live stream would have been, not to its first and last value; a held or settled reading whose interval ends within the replay is published as the replay reaches that time. The replay ends at the point’s first live reading, or 2 s after its last replayed one; a reading still held or settling then waits on the runtime clock from that moment. No heartbeat read is made for a point while it replays. A replayed sample without a source time is handled as a live one, with a warning.

The one-shot CLI read is not subject to the policy. The runtime publishes the effective policies in the capability descriptor (reports, §7), so a consumer can tell why a point is quiet. Because every consumer sees the reduced stream, keep a deadband smaller than the hysteresis of any alarm threshold on the same signal, and do not give a change filter to a point whose every reading is an occurrence (meta.event.every); the runtime logs a warning for the latter.

Test vectors both SDKs run are in test-vectors/report/.

A sample’s ts is the time the reading belongs to:

  • The source time, when the protocol gives the value one: an OPC UA data value’s source timestamp, else its server timestamp. A module sets it on the sample (source_ts in the Rust SDK, source_ts_ms in the C SDK). Only pushed values carry one; a polled read requests none.
  • Else the read time: the completion time of the module call that returned it. Every sample of one read_points call shares that time, and so does every sample of one push delivery. For a module that reads one point per call, the poll pass over a device counts as one call, timed at its first read’s completion. A polled pass over a device therefore has one timestamp and batches into one measurement (§5.5). The runtime sets it; a module does not.

A reading held back by the reporting policy (§5.3) keeps its time. A replayed reading (§5.3 rule 7) always carries its source time. The time has the precision §9 sets, milliseconds.

By default a connector publishes one sample per reading, and the ot-measurement flow turns each one into a thin-edge measurement. With [connector] output = "measurements" the SDK runtime publishes the measurements itself, batched, and samples only for the points a flow reads. This costs a fraction of the mapper CPU per reading, because a message carries hundreds of readings and no JavaScript runs for it. Any other value of output than "samples" and "measurements" is refused.

Measurements. A reading the reporting policy publishes becomes a series in a measurement on te/device/<device>///m/<group>, with the body {"time": "<ts>", "<group>": {"<series>": <value>, ...}}. The group and series are resolved in this order, as the ot-measurement flow resolves them:

  1. the point’s meta.measurement.group and meta.measurement.series
  2. [connector] measurement’s group and series
  3. a split of the point id at measurement.point_separator, when one is set and the id contains it
  4. the protocol id for the group and the point id for the series

Only a good reading of a typed point with a number or a boolean becomes a series: a boolean as 1 or 0, unless measurement.include_boolean = false. A point with meta.measurement = false, a string, a 64-bit integer carried as a string (§4.1) and a raw point never does.

Batches. Every series that shares a device, a group and a message time goes into one message, and a point appears at most once in a message: a second reading of it starts a new one, so no value is overwritten. A message is split before its estimated Cumulocity size passes 15,000 bytes, the estimate being its thin-edge size plus 12 bytes per series, which keeps it under the c8y mapper’s 16,184-byte limit.

Grouping policies. batch.group_by decides the message time, per point, merged key by key from [connector], the device and the point like report:

group_byMessage timePublishedLoss
"time" (default)The readings’ own time, at millisecond precision.When a reading with another time arrives for the group, a point repeats, or the runtime’s pass ends.None. No time is moved.
"frame", with window (1 ms to 60 s)Per layer: its first reading’s time, moved to 1 ms after the previous layer’s time when it is not later.When the window ends, layer by layer.None. A time moves by less than window, plus the 1 ms steps that keep it in order.
"sample", with every (100 ms to 1 h)The sample time.Every every: one series per point holding a good value, changed or not; with aggregate, one per aggregate over the period.By design: readings superseded between two samples, unless an aggregate accounts for them.

Under "frame", a point’s first value in the window goes into the frame’s layer 0, its second into layer 1, and so on, so a repeat never closes a message early and no value is overwritten. Layer times of one topic and policy strictly increase, across frames too, so a point’s values keep their order when source times jitter. A reading that would open a 65th layer publishes the frame’s layers at once and starts a new frame in the same window. A reading that arrives after the window ended opens a new frame.

A batch table that sets group_by and the other policy’s duration is refused; a duration inherited from a level that chose another policy is ignored. Under "sample" a point is left out while it is stale — its device link is not connected, its push delivery failed its check, or its last reading was not good — so a sample never repeats a value the source no longer vouches for. A point raising an event per reading (meta.event.every) is published as under "time".

Aggregates. Under "sample", batch.aggregate names what each period publishes instead of the last value: one of "mean", "min", "max" or "last", or a non-empty list of them without repeats. A table that sets aggregate without group_by chooses "sample" at its own level, so batch = { aggregate = "mean", every = "1s" } is a complete policy; a table that sets group_by = "time" or "frame" with aggregate is refused, and an inherited aggregate the effective policy does not use is ignored. The aggregates are computed over the values the point held during the period, on the device clock, counting the value held when the period started from its start; a boolean counts as 1 or 0. "mean" is time-weighted: each value counts for the good time it held. "min" and "max" are the smallest and largest value held, and "last" the value held at the sample time. Time while the point is stale does not count, and a point with no good time in the period is left out. A string keeps the point’s series name; a list publishes each aggregate as <series>_<aggregate>, each with the point’s unit in the units message. An aggregate uses every good reading, so a point whose effective policy has both aggregate and a report policy is refused, as is a configuration in which a series of an aggregated point has the name of another series of its device and group.

Units. The runtime publishes a measurement topic’s units as a retained message on <topic>/meta, holding {"<group>.<series>": {"unit": "<unit>"}} for every series of the topic with a unit, before the topic’s first measurement and again only when a unit appears, changes or goes away. An emptied map clears the topic with an empty retained message.

Samples. In measurement output a point publishes samples only when a flow reads them: it has meta.alarm, meta.event or meta.parameter (each unless false), or write or read_write access. sample = true publishes them for any consumer, and sample = false publishes none. A sample of a reading that also became a series carries "measured": true (§5), which ot-measurement skips. Link status, the capability descriptor and commands are unchanged.

Flows. ot-alarm and ot-event do not subscribe to measurements, so a batch wakes no JavaScript. Their measurement-series modes (one series with a threshold, one series with an event on every change) are the separate flows ot-alarm-series and ot-event-series.

The runtime lists each device’s effective output and grouping policy in the capability descriptor (outputs, §7). Test vectors both SDKs run are in test-vectors/measurements/.

A connector reads its devices concurrently when its module allows it, and may send several requests to one device at once when the protocol allows it (OPC UA Reads). Throughput then follows the devices’ round-trip times, not the sum of them. Writes, commands and method calls are not concurrent.

One read per device. A device never has more than one read in flight. Its writes, commands and reconnects wait for its read in flight. The report policy (§5.3), measurement output (§5.5), the link status and publishing are applied in the order each device’s results arrive. The results of one read call keep the order of the points requested, and the call’s read time is stamped when it completes (§5.4).

Endpoints and budgets. Every device has an endpoint, named by its module: the host and port it talks to (OPC UA, Modbus TCP, SNMP), the serial port (Modbus RTU), the CAN interface (CAN, CANopen) or the bus (PROFIBUS). Without one, the device is its own endpoint.

KeyWhereTypeDefaultMeaning
max_inflight[connector], [[device]]positive integer4Requests in flight to one endpoint, counting every device on it and every pipelined request. Devices sharing an endpoint use the smallest value among them.
max_inflight_total[connector]positive integer32Requests in flight across all endpoints.

A module caps an endpoint whatever the configuration says: a serial bus and a CAN interface carry 1. A read takes one request of its endpoint’s budget, waiting if none is free, then as many more as are free, up to what it can use; every device on an endpoint therefore makes progress. max_inflight = 1 sends one request at a time to each endpoint, while devices on different endpoints are still read in parallel.

Backoff. An endpoint’s budget in effect halves, to at least 1, when a request is answered with OPC UA BadServerTooBusy or BadResourceUnavailable, or times out while another request to the endpoint is in flight. After 20 successful requests at a reduced budget it grows by one, up to the configured budget. Each change is logged at info. A request refused as busy is sent again within the same call, at most 8 times and within operation_timeout; only then do its points fail. BadTooManyOperations is not a busy answer: a server returns it for a Read larger than it accepts. A timeout with no other request in flight is a link failure, as before.

The capability descriptor lists each endpoint with its devices and its budget (endpoints, §7).

Commands let external actors (cloud operations, other flows, operators) act on a connector — primarily writing points. Commands use a request/result state machine on te/device/<device>/ot/<protocol>/cmd/<verb>/<id> (retained). JSON Schema: schemas/command.schema.json.

init ──▶ executing ──▶ successful
                   └──▶ failed
statusSet byMeaning
initrequesterNew command request, payload includes inputs.
executingconnectorConnector accepted it and is acting.
successfulconnectorCompleted; result may carry output.
failedconnectorFailed; reason set.

The requester publishes the init message; the connector transitions it through the remaining states on the same topic (retained). A clearing (empty retained) message ends the command lifecycle.

Request (status: "init"):

{
"status": "init",
"point": "setpoint",
"value": 21.5,
"value_repr": "number"
}
  • For a typed-writable point, value is the logical value in engineering units — the same units as the sample’s value, i.e. after the point’s transform and map. The SDK maps it back through the value map (§4.3) and then to the raw value (§4.2), and the connector encodes that per the point’s datatype/endianness/word_order. A mapped point is written with its mapped value ("running", not 1); a value with no inverse fails the write.
  • For a raw-writable point, the request MUST instead provide raw (hex) and the connector writes those bytes verbatim.
  • The connector MUST reject (failed) a write to a point whose access does not permit it.

Result (status: "successful"):

{ "status": "successful", "point": "setpoint", "value": 21.5 }

The result echoes value as requested (engineering units), not the raw value written.

Result (status: "failed") — reason is free text; the Modbus wording here is illustrative:

{ "status": "failed", "point": "setpoint", "reason": "modbus exception: illegal data address" }

6.3 Management verbs (standard, SDK-provided)

Section titled “6.3 Management verbs (standard, SDK-provided)”

Beyond point I/O, every connector needs to be (re)configured at runtime: change a poll interval, adjust serial parameters, add a device, etc. Rather than inventing a bespoke operation per protocol (as the legacy Modbus plugin did with c8y_ModbusConfiguration, c8y_SerialConfiguration, c8y_ModbusDevice, c8y_Coils, c8y_Registers), the contract defines a small set of protocol-neutral management verbs. They are implemented once in the SDK runtime — it owns the connector configuration document — so every protocol module gets them for free without any extra code.

A connector that uses the SDK runtime MUST advertise these verbs (and the management feature) in its capability descriptor (§7). All three follow the same init → executing → successful/failed state machine as write, but on the connector’s service command topic:

te/device/main/service/<service>/ot/cmd/<verb>/<id>

A management command changes one connector instance’s configuration file, so it is addressed to that instance by its service_name rather than to a device topic that every instance of the protocol receives (§6.5); the affected device is named in the payload. A connector:

  • MUST act on management verbs only on its own service command topic;
  • MUST reject (failed, naming the service topic in reason) a management verb received on the topic of a device it owns, and any other verb received on its service command topic;
  • MUST echo the request’s origin (§6.4) into every transition, so a bridge can complete the command on the entity it was issued for, which the service topic does not name.

After a successful management command the runtime persists the updated configuration to disk and live-reloads the connector (re-validate, reconnect, reschedule) — no service restart is required. From then on the connector answers the device commands of the devices the new configuration defines (§6.5).

set-config — patch connector configuration

Section titled “set-config — patch connector configuration”

Applies a deep-merged patch to one section of the configuration document. Replaces c8y_ModbusConfiguration (poll/transmit rate) and c8y_SerialConfiguration (serial parameters).

Request (status: "init"):

{
"status": "init",
"target": "connector",
"config": { "poll_interval": "5s", "log_level": "debug" }
}
  • target selects the section to patch: "connector", "mqtt", "connection" (shared protocol defaults, e.g. { "serial": { "baudrate": 19200 } }), or "device:<name>" to patch a single device’s fields (its point list is left untouched unless included).
  • config is deep-merged into the target section (objects merge recursively; scalars and arrays replace).
  • The runtime rejects (failed) a connector patch that sets service_name or protocol: the service name is the address of the management commands themselves, and the protocol selects the module. Both change only by editing the configuration file and restarting the connector.
  • The runtime rejects (failed) a patch that produces an invalid configuration.

Inserts a device (transport + points) into the configuration, or replaces an existing device with the same name. Replaces c8y_ModbusDevice together with the point definitions that c8y_Coils/c8y_Registers used to stage. Child-device registration in the cloud is then handled by the existing registration flow when the device link comes up.

Request (status: "init"):

{
"status": "init",
"device": {
"name": "plc-9",
"protocol_address": { "transport": "tcp", "host": "10.0.0.9", "port": 502, "unit_id": 1 },
"default_mode": "typed",
"point": [
{ "id": "temp", "datatype": "float32", "access": "read_write",
"address": { "table": "holding", "address": 7, "count": 2 } }
]
}
}

The device object uses the same shape as a [[device]] entry in the configuration file (note the point list key is point, matching the file’s [[device.point]]). It replaces the whole entry, so a define-device for a device switched off with enabled = false (§3.3) switches it back on unless the new entry sets enabled = false as well.

Removes the named device (and its points) from the configuration and disconnects it.

{ "status": "init", "device": "plc-9" }

6.4 The write-batch verb (standard, SDK-provided)

Section titled “6.4 The write-batch verb (standard, SDK-provided)”

A parameter set edited in a cloud UI, a recipe download, or a setpoint change that spans several registers must update several points as one request. Rather than have every requester fan out N write commands and reassemble their results, the SDK runtime implements write-batch once, on top of the module’s write: the writes are executed sequentially, in request order, and the batch stops at the first failure (later points are left untouched). The runtime advertises the verb for every module that implements write.

Request (status: "init"):

{
"status": "init",
"writes": [
{ "point": "setpoint", "value": 21.5 },
{ "point": "run_command", "value": true },
{ "point": "mask", "raw": "00ff" }
]
}

Each entry follows the write request rules (value for typed points, raw for raw points). An empty writes array is rejected (failed), so a malformed request cannot succeed without touching the device.

A request MAY carry an origin object: opaque correlation data the requester attaches. The connector MUST NOT interpret it, and MUST echo it verbatim into every transition it publishes for that command (write and write-batch alike). The topic is retained and holds exactly one message, so the result overwrites the request — without the echo, a consumer that starts or restarts afterwards replays the terminal state alone and has lost what the request said. That is what lets a flow still tell which parameter set (§5.2) an acknowledged write belongs to, rather than guessing and retaining a fragment under a name no definition matches.

Transitions: executing carries points (the ids about to be written); the terminal message carries results, one entry per attempted write in order:

{ "status": "successful",
"results": [ { "point": "setpoint", "status": "successful", "value": 21.5 },
{ "point": "run_command", "status": "successful", "value": true } ] }
{ "status": "failed",
"reason": "write to run_command failed: access denied: point run_command is not writable",
"results": [ { "point": "setpoint", "status": "successful", "value": 21.5 },
{ "point": "run_command", "status": "failed",
"reason": "write to run_command failed: access denied: point run_command is not writable" } ] }

The batch is not atomic: a failed batch may have applied the writes listed as successful. A connector MAY implement write-batch natively (e.g. one Modbus FC16 for contiguous registers) as long as it keeps these semantics.

Several connector instances may share a broker — one process running a directory of configurations starts one instance per file, and further processes may run alongside it — and every instance of a protocol subscribes to the device command topics of the whole protocol (te/device/+/ot/<protocol>/cmd/+/+). Each command must still be acted on by exactly one of them. The command topic is retained and holds one message, so a second responder’s transitions overwrite the first’s: a fast failed (“unknown device”) from an instance that does not own the device would replace the real result of the instance that does.

  • A connector MUST act on a device command only when <device> is a device its current configuration defines, and MUST NOT publish anything for a command addressed to any other device — not even failed, since it cannot know whether another instance owns that device. A command for a device no connector owns therefore stays at init; a requester needs its own timeout for that case.
  • Ownership follows the live configuration: a device added or removed by a management verb (§6.3) is answered, or no longer answered, as soon as the change is applied.
  • Management commands are addressed to one instance by its service name (§6.3).
  • A device MUST be defined by at most one instance per protocol on a broker, and every instance MUST have a unique service_name. An SDK runtime starting a directory of configurations warns about both.

write is the only point-I/O verb a conformant connector MUST support (for writable points), and SDK-based connectors additionally provide write-batch and the three management verbs above. A connector whose protocol has callable operations MAY support call-method (§6.6). Connectors MAY support further verbs (e.g. read-now, rescan); any such verb MUST be declared in the capability descriptor (§7) and documented in the connector spec.

6.6 The call-method verb (standard, optional)

Section titled “6.6 The call-method verb (standard, optional)”

Calls a "call_method" point (§3.1), such as an OPC UA method. Request (status: "init"):

{ "status": "init", "point": "multiply", "arguments": [6, 7] }
  • arguments is the list of input arguments, in order; omitted, it is empty. The connector converts them as its spec defines (OPC UA: to the point’s declared inputs). No transform or map applies: arguments are not point values.
  • The command MUST fail when arguments is not an array, and when the point’s access is not "call_method". write and write-batch MUST fail for a "call_method" point.
  • A method call MUST NOT be retried, whatever the failure: the operation may have taken effect even when no answer came back, so a failed result after a timeout does not prove it did not.
  • As after a write, the SDK runtimes reset the device’s reporting state (§5.3) after the command, so the next reading of every point is published.

Result (status: "successful") — outputs lists the output arguments, in order:

{ "status": "successful", "point": "multiply", "outputs": [42] }

Result (status: "failed"):

{ "status": "failed", "point": "fail", "reason": "call rejected: BadInvalidState" }

Like every command, the transitions echo the request’s origin (§6.4).

The descriptor’s methods (§7) lists the methods a connector can call, for instance:

"methods": [
{ "device": "Pump01", "point": "setOperatingLevel", "name": "Set operating level",
"address": { "object_id": "ns=2;i=6", "method_id": "ns=2;i=27", "inputs": ["int64"] } }
]

On thin-edge.io the ot-registration flow turns it into the ot_call_method command capability of each device that has methods, a retained {"methods":[...]} on te/device/<device>///cmd/ot_call_method listing the same entries without device, so the cloud mapper routes method calls to the device; the command flows forward ot_call_method to call-method.

On startup a connector MUST publish a retained capability descriptor to te/device/main/service/<service>/ot/capabilities. JSON Schema: schemas/status.schema.json (capabilities definition).

The fields are protocol-neutral; the values describe what a given connector supports. The example below is the Modbus connector’s descriptor — a CAN or OPC-UA connector publishes the same fields with its own values (and typically "subscribe": true):

{
"protocol": "modbus",
"version": "0.1.0",
"modes": ["raw", "typed"],
"datatypes": ["bool", "int16", "uint16", "int32", "uint32", "float32", "float64"],
"point_kinds": ["coil", "discrete_input", "holding_register", "input_register"],
"command_verbs": ["write", "set-config", "define-device", "remove-device"],
"features": ["polling", "bitfield", "management"],
"subscribe": false,
"point_labels": [
{ "device": "plc-1", "point": "boiler_temp",
"name": "Boiler temp", "description": "Outlet temperature after the heat exchanger" }
],
"parameter_keys": [
{ "device": "plc-1", "point": "boiler_setpoint", "key": "setpoint", "group": "control" },
{ "device": "plc-1", "point": "pump_speed_sp", "fragment": "pump_speed" }
],
"reports": {
"default": { "max_interval": "30m" },
"devices": [ { "device": "plc-1", "report": { "on_change": true } } ],
"points": [
{ "device": "plc-1", "point": "boiler_temp",
"report": { "on_change": true, "deadband": 0.5, "min_interval": "10s", "max_interval": "30m" } }
]
}
}
FieldMeaning
modesOutput modes supported. MUST include at least one of raw/typed.
datatypesSubset of §4 the connector can decode in typed mode.
point_kindsProtocol-specific kinds the connector understands (free strings, documented per spec).
command_verbsVerbs accepted on cmd/<verb>. MUST include write if any point is writable; SDK-based connectors also list write-batch (§6.4) and the management verbs (§6.3), and a connector that calls methods lists call-method (§6.6).
featuresOptional capability tags: polling, subscribe, bitfield, string, bulk_read, …
subscribeWhether the connector supports event-driven (push) reads in addition to polling.
point_labelsThe human-readable name/description of the configured points (§3.1), so a consumer can show something friendlier than the point id. Only points declaring one of them appear, and each entry carries only the fields it declares — no entry means the id is the label, so a configuration that labels nothing adds nothing here. Unlike the fields above, this describes the configuration rather than the connector’s abilities; it lives here because it is static per point, which makes one retained message the right place for it and a per-sample echo the wrong one (§5 samples are a time series).
parameter_keysThe configured points that name their own key inside their parameter sets (meta.parameter.key, §5.2), with the key and any set / group exactly as configured — so a key of the form <set>.<key> names its set too. Also every literal parameter (meta.parameter.fragment, §5.2), as { device, point, fragment } with the fragment as configured. A consumer learns from it which point a key or fragment belongs to before the point samples — after a restart, since samples are not retained, and for a write-only point, which never samples. Only points naming a key or a fragment appear, so a configuration naming neither adds nothing here. Like point_labels, this describes the configuration.
methodsEvery configured "call_method" point (§3.1), labelled or not, with its name / description when it declares them and its address exactly as configured: which methods a device has, what their arguments are (in the address, as the connector spec defines it) and which node each one calls. Methods never sample, so nothing else announces them. Absent when no point is a method. Like point_labels, this describes the configuration.
reportsThe reporting policies (§5.3): default is [connector] report, devices lists each device declaring a report, and points lists the effective (merged) policy of each point whose policy differs from its device’s. A point’s policy is its points entry if it has one, otherwise its device’s entry merged over default. Absent when no report is configured. Like point_labels, this describes the configuration.
outputsMeasurement output (§5.5): one entry per device, { device, output, batch }, with the output ("samples" or "measurements") and the device’s merged batch table, group_by filled in. A point’s own batch is in the configuration only. Absent for a connector in samples output that sets no batch. Like point_labels, this describes the configuration.
endpointsConcurrent reads (§5.6): one entry per endpoint, { endpoint, devices, max_inflight }, with the devices on it and its budget of requests in flight after the module’s cap. The budget in effect after a backoff is logged, not listed here. Like point_labels, this describes the configuration.

Tooling and the conformance suite use the descriptor to decide which tests apply.

The descriptor is retained, so it MUST be republished whenever something it reports changes. Everything except point_labels, parameter_keys, methods, reports, outputs and endpoints is a property of the connector build and so is published once at startup; those five follow the configuration, and a connector MUST therefore republish the descriptor after a management command (§6.3) changes it — a retained message describing the configuration as it was at startup is worse than none. Note also that labelling every point of a large list has a size: two hundred fully labelled points add on the order of ten kilobytes to this one message. That is paid once per (re)publish, not per sample, which is the reason the labels live here rather than in the sample envelope.

  • The connector MUST publish a retained service health message to te/device/main/service/<service>/status/health with at least {"status":"up"|"down","time":"<rfc3339>"} on startup and on health changes, following the thin-edge service health convention.

  • For each device, the connector SHOULD publish a retained link-status message to te/device/<device>/ot/<protocol>/status/link:

    { "status": "connected", "type": "acme-meter-v2", "points": ["boiler_temp", "setpoint"],
    "since": "2026-05-30T09:59:00.000Z" }

    type is the device’s declared type (§3.1), present when it has one: the message is retained and published before any sample, which is what lets a consumer name the device’s parameter sets (§5.2) and its thin-edge entity type from the start — including for a device whose parameters are all write-only and therefore never sampled.

    points lists the id of every point configured on the device, in configuration order. The link status is republished whenever the configuration changes (a management command, a reload, a restart), so this is how a consumer keeping state per point — the parameter twin (§5.2) — learns that a point was removed: missing samples cannot say it, since a write-only point is never sampled. SDK runtimes always include it. A consumer MUST read a status without it as saying nothing about the points, not as a device that has none. The list makes the message grow with the device — roughly the length of each id plus three bytes, so a few-hundred-point device passes 10 KiB — and an MQTT client with a small default packet limit must have it raised (the Rust runtime allows 1 MiB). Device names are unique only within one connector, so a consumer keeps the list per device and protocol.

    with status ∈ {"connected","disconnected","degraded"} and an optional reason.

A connector that hangs is worse than one that fails: a protocol call which never returns blocks the loop that publishes samples, health and link status, so the device goes silent with nothing logged and nothing in the cloud marking it unhealthy. An SDK-based connector is therefore bounded on two levels, both configured in [connector]:

SettingDefaultEffect
operation_timeout30sUpper bound on one protocol-module call (read batch, write, connect, subscribe). Exceeding it is reported as an ordinary transport error, so the existing degraded link and reconnect-with-backoff handling applies.
stall_timeout120sHow long the loop may make no progress before the connector is considered wedged, cancelled and restarted. The MQTT last will then marks the service down, so the outage is visible. Must exceed operation_timeout; 0 disables it.

A connector SHOULD additionally bound its own protocol requests (the Modbus module’s connection.request_timeout_s, the OPC UA module’s connection.request_timeout_s): failing one request fast keeps the poll cycle on schedule, where the runtime’s bound is a backstop that treats the whole batch as failed. The conformance suite checks this behaviour with a peer that accepts the connection and answers nothing (check B5, silent peer).

  • All timestamps MUST be RFC 3339 / ISO 8601, millisecond precision, UTC with a Z suffix.
  • All payloads MUST be UTF-8 JSON.
  • raw hex MUST be lowercase or uppercase consistently within a connector; words SHOULD be space-separated in protocol-natural width (e.g. per 16-bit register for Modbus).
  • Samples for a single point SHOULD be published in read order; the optional seq field lets consumers detect reordering or loss.
  • This contract is versioned (Version header). Connectors declare the contract version they target in their capability descriptor’s version (their own version) and SHOULD document the contract version they implement in their spec.
  • Backward-incompatible changes to topics, required fields, or the command state machine require a new contract major version and an RFC.

A connector is contract-conformant when it:

  1. publishes valid samples (§5) for every configured point in its declared modes,
  2. publishes a valid capability descriptor (§7) and health/status (§8),
  3. implements the write verb (§6) for all writable points (SDK-based connectors get write-batch for free),
  4. validates its configuration (§3) and protocol-specific schemas,
  5. passes the shared conformance suite, including the golden decode vectors for every typed datatype it advertises.

See the conformance document for the executable definition of these requirements.