Cumulocity operation shims for the OT connector

These files translate the legacy Cumulocity operations the Python Modbus plugin shipped (under the repo-root operations/) into the generic OT command model of the new connector. They are the Cumulocity-specific glue: each one maps a cloud operation onto a protocol-neutral ot_<verb> thin-edge command. The ot-command-forward flow then bridges that command to the connector’s cmd/<verb> topic, the connector (or the SDK runtime, for management verbs) acts on it, and ot-command-result mirrors the result back so the cloud operation completes.

Management verbs (set-config, define-device, remove-device) change one connector instance’s configuration, so they go to that instance’s service topic (te/device/main/service/<service>/ot/cmd/<verb>/<id>, contract §6.3) rather than a device topic. ot-command-forward uses the command’s service field, else tedge-dot-<protocol> — the default service_name of a connector config. When the connector’s config sets another service_name (e.g. several configurations of one protocol), name the service: c8y-fieldbus-import sets it from FIELDBUS_SERVICE; the c8y_ModbusConfiguration/c8y_SerialConfiguration templates always use the default.

 c8y operation ─▶ c8y-mapper ─▶ cmd/ot_<verb> ─▶ ot-command-forward ─▶ ot/<protocol>/cmd/<verb> ─▶ connector
                                       ▲                                                                │
 operation SUCCESSFUL ◀── c8y-mapper ──┴──────────────── ot-command-result ◀───────────────────────────┘
Legacy operationShim fileGeneric commandVerbHandled by
c8y_SetRegisterc8y_SetRegisterot_writewriteprotocol module
c8y_SetCoilc8y_SetCoilot_write_coilwrite-coilprotocol module
c8y_ModbusConfigurationc8y_ModbusConfigurationot_set_configset-configSDK runtime
c8y_SerialConfigurationc8y_SerialConfigurationot_set_configset-configSDK runtime
c8y_ModbusDevice (+ c8y_Coils/c8y_Registers)c8y_ModbusDevice → c8y-fieldbus-importot_define_devicedefine-deviceSDK runtime
c8y_ParameterUpdate (device parameters)none here — the tedge-parameter-plugin’s c8y_ParameterUpdate.templateparameter_updatewrite-batch (reshaped by ot-command-forward)SDK runtime

c8y_Coils and c8y_Registers no longer have standalone shims: the legacy operations only staged point definitions in TOML that c8y_ModbusDevice later assembled. In the generic model the points travel inside the ot_define_device payload (the device.point[] array), so defining a device and its points is a single operation.

The generic verbs are defined in the OT connector contract §6 and implemented once in the SDK runtime (management verbs) or the protocol module (write), so the same shims work for any SDK-based connector — only the operation fragment names are Cumulocity- and Modbus-specific.

The shims build the generic command input from the cloud operation payload. The generic model is point-name based (it references connector config point ids), not raw protocol coordinates, so the operation payloads carry logical fields:

// c8y_SetRegister / c8y_SetCoil
{ "c8y_SetRegister": { "point": "boiler_setpoint", "value": 21.5 } }
{ "c8y_SetCoil": { "point": "pump_run", "value": true } }
// c8y_ModbusConfiguration (only pollingRate maps; transmitRate corresponds to connector.report.min_interval)
{ "c8y_ModbusConfiguration": { "pollingRate": "5s" } }
// c8y_SerialConfiguration
{ "c8y_SerialConfiguration": { "baudRate": 19200, "stopBits": 1, "parity": "N", "dataBits": 8 } }
// c8y_ModbusDevice, shape 1: the stock Cloud Fieldbus UI payload. The c8y-fieldbus-import
// script creates the child's external identity, fetches the c8y_ModbusDeviceType MO named by
// `type` via the mapper's c8y proxy, and translates its c8y_Registers/c8y_Coils into points.
{ "c8y_ModbusDevice": {
"protocol": "TCP", "address": 1, "ipAddress": "10.0.0.9",
"id": "<child MO id>", "name": "plc-9",
"type": "/inventory/managedObjects/<c8y_ModbusDeviceType MO id>"
} }
// c8y_ModbusDevice, shape 2: a device shaped like a [[device]] config entry (passed through)
{ "c8y_ModbusDevice": { "device": {
"name": "plc-9",
"protocol_address": { "transport": "tcp", "host": "10.0.0.9", "port": 502, "unit_id": 1 },
"default_mode": "typed",
"point": [
{ "id": "temp", "datatype": "float32", "access": "read_write",
"address": { "table": "holding", "address": 7, "count": 2 } }
]
} } }

c8y_ModbusDevice is a command shim (the mapper executes c8y-fieldbus-import, legacy-plugin style) rather than an [exec.workflow] mapping: the Cloud Fieldbus path needs HTTP against the mapper’s local c8y proxy, which the tedge flows JS runtime cannot do (no fetch/XMLHttpRequest — see the status update in RFC 0002). The register translation rules (datatype, transform, meta.measurement naming, coils) are documented in the script header and unit-tested offline by cloud/modbus/tests/test_fieldbus_import.sh.

// c8y_ParameterUpdate — sent by the Cumulocity "Parameters" tab for one parameter set. The set
// name (<set>) is the Digital Twin Manager identifier; the whole operation is passed to the
// parameter_update command as `operation` and ot-command-forward turns it into one write-batch.
{ "c8y_ParameterUpdate": {}, "c8y_ParameterUpdate_acme_meter_v2_control_parameters": {},
"acme_meter_v2_control_parameters": { "temp_u16": 4343, "coil_rw": true } }

Device parameters are protocol-neutral and need no operation file in this repository: the c8y mapper binds .template files by fragment name, so only one template may exist for c8y_ParameterUpdate, and that one belongs to the tedge-parameter-plugin (install it alongside tedge-dot). Its template maps the operation onto the parameter_update command with the whole operation as operation. ot-registration advertises parameter_update on every OT child device (a retained {} on te/device/<device>///cmd/parameter_update), the mapper symlinks the plugin’s template for the child, and the OT flows handle the resulting command — nothing else does, because tedge-agent only runs workflows for its own entity. On the main device the plugin’s own workflow and parameter-set scripts keep working untouched. The Parameters tab only renders sets that have a Digital Twin Manager property definition, which a tenant admin registers once (the device never calls the DTM service — device users lack the roles anyway). tedge-dot describe prints exactly those definitions from the connector configs — by default every config in /etc/tedge/plugins/ot, the directory the service runs, with a set shared by several of them rendered once (-c <file-or-dir>, repeatable, narrows or widens that):

Terminal window
# One definition per line, and the DTM service takes one per request — a configuration that
# groups its parameters (§5.2) renders several. `</dev/null` matters: without it c8y reads the
# loop's stdin as its own input pipeline and the remaining definitions are never registered.
defs=$(mktemp) one=$(mktemp)
trap 'rm -f "$defs" "$one"' EXIT
tedge-dot describe --compact > "$defs"
# Read from a file, not a pipe: a `while` on the right of a pipe runs in a subshell, where
# `exit 1` would abort only the loop and leave the script reporting success.
while read -r definition; do
printf '%s' "$definition" > "$one"
C8Y_SETTINGS_CI=true c8y api POST /service/dtm/definitions/properties --data "@$one" </dev/null ||
exit 1 # stop at the first rejected definition rather than reporting only the last
done < "$defs"

(or create it by hand in the DTM UI: identifier = the set name, one property per point id).

A DTM identifier is tenant-wide, so the set name is derived from the device type the configuration declares — <type>_<group>_parameters, e.g. acme_meter_v2_control_parameters (contract §5.2). Give every device a type (on the [[device]], or once in the point library it references): without one the sets fall back to <protocol>_control_parameters, which every other device type on that protocol also falls back to, and the definitions would overwrite each other in the tenant. describe warns when a device exposes parameters without a type.

Renaming a set leaves the old twin fragment retained under its old name (and mirrored into the managed object), so clear it once per device after changing a name:

Terminal window
tedge mqtt pub -r -q 1 'te/device/plc1///twin/modbus_parameters' ''

The legacy operations carried raw register/coil addresses and per-register scaling. Those now live in connector config (point address) and flows (scaling), so the cloud-facing operation only needs the logical point id and value. Adapt the input.* jq expressions in each shim if your Cumulocity operation templates use different field names.

Copy the shim files into the device’s Cumulocity operations directory and the bridge flows into the c8y mapper. Operations that target the OT child devices (c8y_SetRegister, c8y_SetCoil) must be installed as templates (.template suffix): the mapper instantiates a template per child device that advertises the matching ot_* command capability, which ot-registration publishes. Gateway-level operations (c8y_ModbusDevice, c8y_ModbusConfiguration, c8y_SerialConfiguration) are installed as plain files so they land in the main device’s supported operations. Device parameters need the tedge-parameter-plugin package, nothing from here (cloud/modbus/Dockerfile.tedge is the tested layout):

Terminal window
sudo apt-get install tedge-parameter-plugin # thin-edge community repo: owns c8y_ParameterUpdate
sudo cp operations/c8y_SetRegister /etc/tedge/operations/c8y/c8y_SetRegister.template
sudo cp operations/c8y_SetCoil /etc/tedge/operations/c8y/c8y_SetCoil.template
sudo cp operations/c8y_ModbusDevice operations/c8y_ModbusConfiguration operations/c8y_SerialConfiguration /etc/tedge/operations/c8y/
sudo install -m 0755 operations/c8y-fieldbus-import /usr/bin/c8y-fieldbus-import # needs jq + curl
# The three flows below are already in place on a packaged install; from a
# source checkout, copy them yourself (see ../flows/README.md):
sudo cp -Ra flows/ot-command-forward flows/ot-command-result /etc/tedge/mappers/c8y/flows/
sudo cp -Ra flows/ot-parameter-state /etc/tedge/mappers/c8y/flows/

Set each flow’s params.toml protocol (forward) / command_prefix (result) if you are not using the defaults (modbus / ot_).